FELEMENTAR Analysensysteme is the major German manufacturer of analytical instruments
for non-metallic elements such as carbon, nitrogen, sulfur, hydrogen and oxygen. For a century now, elemental analysers have been developed in Hanau for all kinds of organic and most inorganic substances and compounds. Please review the instrument range below


 VarioMAX CN/CHN/CNS

Top


Vario Max In a significant step forward, Elementar developed a complete family of instruments for N/CN, CNS and CHN analysis for sample sizes of up to several grams. For special applications in agricultural research, protein determination in food and feed, CN analysis in soil or environmental samples to only name a few.With this instrument, the very fast and environmentally friendly Dumas method applied for macro samples becomes a new dimension in instrumentation and preferred alternative to the Kjeldahl method. The Vario MAX provides the maximum performance in a minimum space requirement.
MAX stands for maximum user advantage:
  • Samples up to max. 5 g or 5 ml volume can be analyzed, and a few mg for micro samples
  • Fully applicable for liquid and solid samples
  • Complete combustion gas analysis
  • Three stage gas drying process
  • Highly stable factory calibration means that more time is spent analyzing samples
  • Almost unlimited reuse of stainless steel crucibles
  • Low maintenance and superior reliability means that the VarioMAX can be left for overnight operation
  • PC operation under Windows®

  Rapid N III Nitrogen/Protein analyser

Top

 

Rapid N Applying the Dumas combustion method to the automatic N/protein determination in macro samples of agricultural products had its origin at Heraeus in Hanau. Today, this technique is replacing the classical Kjeldahl method with worldwide cooperative test trials clearly proving the correlation of Dumas and Kjeldahl analytical results. This is the basis for a growing number of national and international standards for N/Protein analysis according to the combustion method.

The N/Protein analyser rapid N is setting the instrument standard for a fully automatic and fast instrument in routine analysis of samples such as food or feed with a sample weight of up to 1 g and an analysis time of approx. 5 minutes.

Features of the rapid N:

  • Automatic control and measurement of all combustion gases
  • Integrated 39 position autosampler capable of accommodating large samples such as pellets (solids) or capsules (liquids). Optional 80 position sampler can be specified.
  • Optimal combustion guaranteed with the integrated oxygen flow sensor.
  • Robust steel combustion tubes, economy-priced and regenerable tube fillings as well as use of CO2 carrier gas ensures a lower costs per analysis.
  • The new rapid N III generation operates under Windows software and employs Tungsten as a reduction method, allowing for up to 4 times longer lifetime of the reduction tube.

  Vario EL Micro- and macro CHNOS elemental analyser

Top

 

Vario EL Concept and performance of the universal analyser vario EL are setting the new standards in CHNOS elemental analysis. The highest analytical precision is being performed, regardless whether less than 1 mg of pharmaceutical products or 800 mg of soil have to be analyzed. Volatile gasoline or temperature-resistant silicium carbide can be analyzed just as well as coal, food or sludge - without limitations for the elements, for CHNS simultaneously or optimized for combinations as CNS, CHN, CN, N, S and O.

The patented gas component separation, based on the purge-and-trap principle, results in an extremely high dynamic range for element contents and concentration ratios, as well as lower detection sensitivity and the automatic optimization of analysis time.

All requirements for the micro and macro samples are met by means of one basic instrument. New tasks do not require an additional instrument - vario EL is variable and adjustable to new requirements.

 


  Vario Trace & IRMS

Top

 
Vario Trace
Vario Trace
IRMS
IRMS

In addition to the variable universal analyser vario EL, there are special versions available, e.g., vario TRACE N and S with Liquid Injection.

Isotopic Ratio Mass Spectroscopy (IRMS)is now a matter of simple routine analysis for a multitude of applications.


  LiquiTOC

Top

 

LiquiTOC Elementar has long been known for their innovation in combustion technologies, solving problems that others have tolerated in the past. This was always evident in the HighTOC a premium high temperature combustion TOC product with matrix separation and complete gas flow control. The LiquiTOC is the latest in the TOC range, offering a more cost effective solution without the compromise.

The unique combustion system (patent applied for) actually removes the analyte from the potentially troublesome sample matrix prior to any exposure to the combustion catalyst. In addition to the reduced maintenance times/costs, this also allows the LiquiTOC to perform the measurement of POC(Purgeable Organic Carbon), TIC (Total Inorganic Carbon) and NPOC (Non-purgeable Organic Carbon) in one singular sample injection. This is combined with many other features of its predecessor make it one of the most advanced but user friendly TOC systems available on the market today. Such a versatile instrument would not be complete without an impressive analytical range, from less than 10ppb up to 10,000ppm Carbon.

PC control is standard, allowing the user to run in the mode of their choice with either a manual sampling system or a choice of 36 or 53 position samplers (with stirrer option). Analysis of solid samples is extremely simple to perform with the optional solids sampling system.

  HighTOC II

Top

 

HighTOC II

The TOC analyser that can handle practically anything, the HighTOC has long been setting the standards in high temperature combustion TOC analysis. The specifications speak for themselves in making the HighTOC a cut above the rest.

  • Wide bore tubing allowing for large particles to enter the analyser.
  • Unique dynamic furnace for primary combustion of the sample.
  • Two stage combustion system that separates sample matrix from the analyte avoiding the poisoning of the catalyst.
  • Three stage drying process that allows up to 4ml of sample to be injected into the furnace.
  • Multi-range NDIR detectors allow a range from 0.5ppm to 10,000ppm with minimal calibration.